Working on the Parasolid importer of CAD Exchanger I had a new chance to observe specificities of another modeling kernel used to describe a B-Rep (Boundary Representation) model. This post highlights a few high-level differences between Parasolid, ACIS and Open CASCADE related to data models.

Comparing to ACIS, Parasolid seems to use a smaller set of primitives. Of course, there are typical elementary curves and surfaces (lines, circles, planes, cylinders, ...), NURBS, basic swept surfaces (revolution, extrusion), offsets. Parasolid defines geometrical object orientation right at the geometrical level by specifying a boolean flag at each curve or surface. An original surface normal is defined by cross-product of U and V derivatives, and can be confirmed or reversed by that boolean flag. ACIS defines normals by using special values of some key parameters, ignoring U and V parameterization. For instance, a sphere with a normal oriented inward would be defined in ACIS as having a negative radius. If you remember, Open CASCADE defines orientation as attached to the topology entity (face for surface, edge for curve).

Transformations in Parasolid can only be applied to component instances in assemblies. ACIS uses transformations only attached to bodies (the top-level entity which is a collection of solids). Open CASCADE can use location at any topology level, from vertex to arbitrary compound. This flexibility allows to reduce the model memory footprint – for instance, a solid box can be represented by single face with 6 different locations. The downside, however, is that you must take extra pre-cautions to not unintentionally modify shared objects, e.g. by creating copies as needed.
Unlike Open CASCADE, both ACIS and Parasolid often share underlying geometries – faces referring to the same surface are quite common in each. Open CASCADE discourages this to prevent modifications. Another benefit, which I realized recently – reduce data race risks in multi-threaded applications.

Among Parasolid geometrical types, I found just a couple of most interesting. The first one, which does not present in ACIS and Open CASCADE, is an intersection curve. An intersection curve is defined by a set of points, two surfaces being intersected and a law to define tangents and parameterization of the curve.
Another one is a rolling_ball_blend surface defined by two support surfaces, spine curve and a ball radius (see image below). Although, ACIS also has such type, the kinds of supports are often different. Whereas ACIS often uses support curves (which it calls ‘spring curves’), Parasolid most often uses surfaces. This added extra challenge to implement conversion as Open CASCADE’s GeomFill_Pipe (I described in the past) does not offer such combination.



Parasolid does not offer that broad set of procedural surfaces that ACIS does (variable_blend, net, skin, tube, law, etc). However it still has a larger set than Open CASCADE which is based on the STEP ISO010303-42 standard. Open CASCADE set is really a subset of what two other offer, except maybe support of Bezier curves and surfaces, and the fact that pcurve can have any type, not just B-Spline as two kernels require.

All 3 kernels have a concept of 3D and 2D representations for face boundaries. Parasolid has a notion of ‘fin’ or ‘half-edge’, and ACIS uses ‘coedge’ which is an entity referred by face’s loops and in its turn, refers to edge and optionally a p-curve. Interestingly, in Parasolid it can have either 3D or 2D representation but not both (though I did encounter one file in 1000+) that violated this requirement.

As far as tolerances are concerned, Parasolid, like Open CASCADE, does use local tolerances attached to the topological entities. ACIS introduced local tolerances in some intermediate versions only.

Similar to ACIS-SAT, the Parasolid-XT file format has evolved from version to version. Unlike ACIS, it is virtually human-unreadable due to use of numbers as type identifiers. Parasolid uses a concept of schemas that define entities type number, field layout, etc. To support backward compatibility, they introduced dynamic extension by embedding schema definitions into the file itself. Open CASCADE file format has never changed for last 15 years at least.
Share
Tweet
Pin
Share
3 comments
(Repost from www.cadexchanger.com)

October 26, 2010.
CAD Exchanger 2.0.2 Beta is available
This version introduces Parasolid-XT importer. We decided to follow an effective approach used for ACIS-SAT by first proposing it to Beta customers and addressing their feedback. If you would like to join the Invitational Beta, drop us an email at info@cadexchanger.com. Public release should become available later this quarter or early 2011.

GUI and CLI (Command Line Interface) versions are available immediately. SDK should be available shortly.

Share
Tweet
Pin
Share
No comments
Newer Posts
Older Posts

Subscribe for the new posts

Blog Archive

  • August 2015 (2)
  • May 2014 (1)
  • November 2013 (1)
  • June 2013 (1)
  • May 2013 (1)
  • November 2012 (2)
  • November 2011 (1)
  • June 2011 (3)
  • May 2011 (2)
  • March 2011 (1)
  • February 2011 (1)
  • November 2010 (2)
  • October 2010 (2)
  • September 2010 (1)
  • August 2010 (1)
  • July 2010 (1)
  • June 2010 (1)
  • May 2010 (1)
  • April 2010 (2)
  • March 2010 (2)
  • January 2010 (2)
  • December 2009 (1)
  • November 2009 (2)
  • October 2009 (3)
  • August 2009 (2)
  • July 2009 (3)
  • June 2009 (4)
  • May 2009 (3)
  • April 2009 (2)
  • March 2009 (5)
  • February 2009 (5)
  • January 2009 (5)
  • December 2008 (11)
  • November 2008 (8)

Loading...

Followers

Created by ThemeXpose